Juniper Netscreen
OIDs for CPU:
CPU for the last minute: .1.3.6.1.4.1.3224.16.1.2.0
CPU for the last 5 minutes: .1.3.6.1.4.1.3224.16.1.3.0
CPU for the last 15 minutes: .1.3.6.1.4.1.3224.16.1.4.0
OIDs for memory:
Memory Allocated: .1.3.6.1.4.1.3224.16.2.1.0
Memory Available: .1.3.6.1.4.1.3224.16.2.2.0
Memory Fragmented: .1.3.6.1.4.1.3224.16.2.3.0
OIDs for sessions:
Sessions Allocated: .1.3.6.1.4.1.3224.16.3.2.0
Sessions Maximum: .1.3.6.1.4.1.3224.16.3.3.0
Sessions Failed: .1.3.6.1.4.1.3224.16.3.4.0
Walk Redundant Interfaces
- I had a problem finding OID's for redundant subinterfaces on my SSG-320M's, meaning I have two physical cables to my switches, and each numbered interface is just a vlan on that trunk going to the two switches.
Here's a nifty php script to walk and generate a basic cfg file. - Tim Connolly
Attachments
-
Juniper-Redundant-Interface-Walker.rtf
(1.9 KB) -
added by human 16 months ago.
Cleaner version with Interface IP in description